1.Product Description: Pediatric disposable spo2 sensor,0.9m
2.Connector Type:7Pin>DB9
3.Spo2 sensor type: Pediatric disposable spo2 sensor
4.Product Material:New import TPU raw materials manufacturing, can reach the fire rating, the requirements on biocompatibility conforms to CE, FDA and other international requirements, the commonly used color optional blue or grey
5.The core components:Made with global precision infrared sensor, wavelength accuracy can reach + / - 3 nm
6.Compliance standard:ISO9919:2005,AAMI-EC53-1995-R2001,DIN EN ISO 9706-2010
7.Compatibility:,Ohmeda,Mindray,BCI,Masimo,Nihon Kohden
8.Delivery time:2-10 working days,by DHL/UPS/FEDEX/TNT.etc
9.product clarification:SpO2 Sensor Probe often show in a adhesive way, which in the type of non-woven fabric, sponge of comfort, comfort foam tape, transparent breathable membrane, and oxygen probe tape are most popular.
We provide various specifications, which suitable to various brands of disposable and split type probe and also provide all kinds of adhesive tape for your choice.
10.product working time:It’s a disposable SpO2 Sensor, should be replaced once for each case of patient, and the working time need be controlled within 72 hours. And if still need to continue use, please evaluate first, and do inspect when use.
11.product using tips:*Monitoring Part Selecting:preferred not lien artery catheter, blood pressure cuff, or intravenous infusion path ways of the extremities.
*Probe Application Position: in a comfortable level. If it is too tight, will cause the vein of rhythmic beating. If it is too loose, light produced by the transmitter can’t measuring the position completely,may cause a false readings.
*If the viscous enough,the sticky disposable blood oxygen probe can be used in the same patients.
*Check every 8 hours for the paste probe monitoring position, if necessary, can replace the position.
*Interference light can affect the sensor monitoring value, during the use of the transducer we need to avoid strong light interference. Such as sunlight, light, infrared heat lamp and phototherapy etc.
*Tissue edema will affect the readings of SpO2 saturation, so should choose no edema site for monitoring.
*In order to make the disposable probe work under the best situation, the patient should reduce the frequency of activities.